Features

Luxury Shower Style

Luxury Shower Style

The shower is used so often, day in and day out, that it has become an essential part of our daily lives. Panasonic sees the shower as an important element to not only keep our bodies clean, but also to refresh our minds and keep us healthy. We make shower time more comfortable by raising the basic performance of your shower while also enhancing comfort, health, and safety. The end result is a more luxurious, more rewarding shower experience.

Rain Shower

One-touch Inner Lid
Easily adjust the shower rail according to your height preference (min. length 770mm, max. length: 1165mm).

Easy Adjust Diverter
Panasonic rain shower head diverter can be operated easily without hassle.

*Only valid for DH-3NDP1MSR and DH-3NP2MSR

Rain Shower

Low Noise Operation

Low Noise DC Pump
The DC pump gives you both a powerful water flow and low noise operation. You can feel free to take a shower late at night or after the family has gone to sleep.

*Made In Japan DC pump

Low Noise Operation

The Comfort of a Steady Temperature

Built-in Temperature Sensor
The temperature sensor is built into the main unit lets you maintain a constant shower temperature.

You don’t need to worry about the temperature changing while you shower, so you can enjoy showering in comfort.

The Comfort of a Steady Temperature

Easy

Easy Switching Shower

3-Way Shower Selector
The switch selector on the shower head gives you 3-way control of the shower flow: Normal, Spot, or Wide.

The Selector Button is built into the grip, so it’s easy to press, and you can switch the shower flow with a single hand.

Easy Switching Shower

Easy & Safety Push

One Push ON/OFF Switch
A large, easy-to-press ON/OFF switch on the main unit. The large button can be pressed even while showering with your eyes closed. One push lets you turn off the water and the electricity. It’s a quicker, more convenient way to turn off the water.

Easy & Safety Push

Maintaining Cleanliness

The antibacterial material containing Ag+ (silver) prevents mold generation. It prevents mold in the shower head, which often occurs in the humid environment of the bathroom, so the shower head remains constantly clean.

Maintaining Cleanliness

9-Safety Points

9Water Flow Sensor

• Cut off power supply if the water flow is too low which can lead to water temperature from becoming very hot
• Prevent over-heating

1Insulated Structure

• Comply with IEC 60529 for protection
• provided by enclosure against access to hazardous parts with a finger and foreign objects
• Prevent electrical shock

2Water Splash Proof Case Cover

• Comply with IEC 60529 (IP25) for protection
• The joint between the front plate and back plate has a water-resistant design
• Prevent fire/electrical shock

3Non-Flammable Material Compliance

• UL-94-V0 Classification Material
• Self extinguish, noncombustible material for external casing (Front Plate/Back Plate)
• Prevent fire

4One Push ON/OFF Switch / Main Switch ON/OFF

• Switch off both main power line and water supply line directly
*The R Series only switches ON/OFF the main power line.
• Prevent burning and electric shock

5Manual Reset Thermostat

• Cut off power supply in the event of component failure resulting in continuous heating in abnormal conditions
• Prevent fire

6Durable Copper Heater Unit*¹ / Reinforced Polyamide Heater Unit*²

• Self extinguish, non-combustible
• material for container
• Heat Resistant
• Prevent fire

*¹ 3ND1, 3NDP1, 4HP1, 3NS2, 3NP2, 3NS1
*² 3MP2, 3MP1, 3MT1, 3MS1, 3RP1, 3RL1

7Auto Thermal Cut-Out (55°C)

• Cut off power supply in the event of water temperature exceeds hazards limit
• Prevent from burns (first-degree burn)

8Built-in Earth Leakage Breaker (ELB)

• Mechanical Type, Double Pole Switch
• Double safety as it cuts off both neutral and live line completely if electricity leakage occurs
• Power supply cuts off automatically when unit has current leakage
• Prevent electric shock

9Water Flow Sensor

• Cut off power supply if the water flow is too low which can lead to water temperature from becoming very hot
• Prevent over-heating

1Insulated Structure

• Comply with IEC 60529 for protection
• provided by enclosure against access to hazardous parts with a finger and foreign objects
• Prevent electrical shock

2Water Splash Proof Case Cover

• Comply with IEC 60529 (IP25) for protection
• The joint between the front plate and back plate has a water-resistant design
• Prevent fire/electrical shock

3Non-Flammable Material Compliance

• UL-94-V0 Classification Material
• Self extinguish, noncombustible material for external casing (Front Plate/Back Plate)
• Prevent fire

4One Push ON/OFF Switch / Main Switch ON/OFF

• Switch off both main power line and water supply line directly
*The R Series only switches ON/OFF the main power line.
• Prevent burning and electric shock

5Manual Reset Thermostat

• Cut off power supply in the event of component failure resulting in continuous heating in abnormal conditions
• Prevent fire

6Durable Copper Heater Unit*¹ / Reinforced Polyamide Heater Unit*²

• Self extinguish, non-combustible
• material for container
• Heat Resistant
• Prevent fire

*¹ 3ND1, 3NDP1, 4HP1, 3NS2, 3NP2, 3NS1
*² 3MP2, 3MP1, 3MT1, 3MS1, 3RP1, 3RL1

7Auto Thermal Cut-Out (55°C)

• Cut off power supply in the event of water temperature exceeds hazards limit
• Prevent from burns (first-degree burn)

8Built-in Earth Leakage Breaker (ELB)

• Mechanical Type, Double Pole Switch
• Double safety as it cuts off both neutral and live line completely if electricity leakage occurs
• Power supply cuts off automatically when unit has current leakage
• Prevent electric shock

9Water Flow Sensor

• Cut off power supply if the water flow is too low which can lead to water temperature from becoming very hot
• Prevent over-heating

Japan Technology

Control Circuit Board

Control Circuit Board

Temperature Sensor

Temperature Sensor

ELB

ELB

DC Pump*

DC Pump*

Triac*

Triac*